Product Details:
ATLAS COPCO PF3107-G-IB-HW belongs to the Power Focus 3000 series, it is a single-channel graphic HMI tightening controller with internal bus interface. The letter G represents graphic version equipped with built-in LCD display and full-function keypad. Operators can view torque curve, angle curve, batch counter, fastening result and fault codes directly on the local panel, and complete parameter adjustment, program editing and on-site diagnosis without connecting external PC software. IB stands for internal bus interface variant, designed for dedicated communication connection with matched station control modules.
Basic Parameters
Compatible tools: Tensor 3 series electric nutrunners
Max stored programs: 128 sets
Input voltage: 100‑120V / 200‑240V AC, 50/60Hz
Power consumption: 240W
Mounting method: 19 inch cabinet mounting
Communication: Internal bus, isolated digital input and output terminals
License levels: Standard, Advanced Supported Tightening Strategies
Torque control with angle monitoring
Angle control with torque supervision
Dynatork prevailing torque compensation
Yield point detection
Fastener seating control Core Functions
Batch counting and Poka-Yoke error proofing
Statistical process value recording
Complete tightening data storage: torque, angle, timestamp, batch ID, tool serial number, OK/NOK result
Local curve display and alarm code inquiry
Internal bus communication for data exchange with station auxiliary modules Hardware Specifications & Environmental Features
Built-in EMC filter and surge suppression circuit
Operating ambient temperature: 0°C ~ +45°C
Protection grade: IP20 for controller cabinet
HW suffix: specific hardware revision with internal bus communication board
Status: Discontinued original model, available as replacement spare part Test items before shipment
Tool communication test
Internal bus communication test
Tightening function test
Curve display inspection
Firmware compatibility verification
Industry Applications: Applied in petrochemical auxiliary skids, gas flow control systems, boiler closed-loop control rooms and water treatment facilities for conventional analog signal acquisition and valve regulating output.
Note: Confirm SAM combined I/O feature and hardware revision before ordering
This is from our current stock.