Product Details:
ATLAS COPCO PF3007-C-HW belongs to the Power Focus 3000 series, it is a compact single-channel industrial tightening controller without local graphic display panel. The letter C represents compact type, there is no LCD screen and physical operation keypad on the front. All tightening program setup, parameter adjustment, function configuration, data backup and equipment fault diagnosis need to be completed remotely via the official ToolsTalk PF configuration software on external PC. This controller is designed for automated bolt fastening stations controlled by digital I/O signals, suitable for fixed assembly stations that do not require frequent on-site manual operation.
Basic Parameters
Compatible tools: Tensor 3 series electric nutrunners
Max stored programs: 128 sets
Input voltage: 100‑120V / 200‑240V AC, 50/60Hz
Power consumption: 240W
Mounting method: 19 inch cabinet mounting
Communication: isolated digital input and output terminals, serial port
License levels: Standard, Advanced Supported Tightening Strategies
Torque control with angle monitoring
Angle control with torque supervision
Dynatork prevailing torque compensation
Yield point detection
Fastener seating control Core Functions
Batch counting and Poka-Yoke error proofing
Statistical process value recording
Complete tightening data storage: torque, angle, timestamp, batch ID, tool serial number, OK/NOK result
Support RBU rapid backup unit for fast program recovery
Digital I/O signal for tool start trigger, station interlock and status feedback Hardware Specifications & Environmental Features
Built-in EMC filter and surge suppression circuit
Operating ambient temperature: 0°C ~ +45°C
Protection grade: IP20 for controller cabinet
HW suffix: specific hardware revision with standard I/O board
Status: Discontinued original model, available as replacement spare part Test items before shipment
Tool communication test
Digital I/O signal test
Tightening function test
Firmware compatibility verification
Industry Applications: Applied in petrochemical auxiliary skids, gas flow control systems, boiler closed-loop control rooms and water treatment facilities for conventional analog signal acquisition and valve regulating output.
Note: Confirm SAM combined I/O feature and hardware revision before ordering
This is from our current stock.